12 INCH PATIENT MONITOR PM-LP12A NIBP , SPO2 , TEMP, RESP, ECG, ETC02 TECHNICAL SPECIFICATIONS Multi-parameter Patient Monitor
- CE, ISO13485
- SFDA: Class ���b
- Anti-electroshock degree: Class���equipment (internal power supply)
- TEMP/SpO 2 /NIBP: BF
- ECG/Resp: CF Quality Standards and Classification
- Adult/Pediatric/Neonatal/Medicine /Surgery/Operating Room/ICU/CCU Application Range
- 12��� realcolorTFTscreen Resolution:800��600
- One alarm indicator(yellow/red)
- One working indicator(green)
- One battery charge stateindicator(green)
- Three modes in accordance with the alarm state Display Operating Environment :
- Temperature: 0 ~ 40 ���
- Humidity: ���85%
- Altitude: -500~4600m Transport and Storage Environment :
- Temperature: -20~60 ���
- Humidity: ���93%
- Altitude: -500~13100m Environment
- AC: 100 ~ 240V, 50Hz/60Hz
- DC: Built-in rechargeable battery
- Battery: 5200mAh 11.1V lithium battery 4h operating afterf ull charge(one piece) 5min operating after low battery alarm Power Requirements
- Equipment: 300mm��286mm��155 mm(about); 4.5kg(about)
- Package : 350mm ��380 mm �� 300mm(about); 6.5kg(about) Dimension and Weight
- Trend diagram/table: 7x24h
- NIBP review: 400 events
- Wave review: 100min
- Alarm review: 100 alarm events
- Support drug concentration titration analysis Date Storage
- Range: 0 ~ 100%
- Resolution: 1%
- Precision: 70% ~ 100%: ��2 DIGIT 0% ~ 69%: ��no definition given SpO2
- Range: 20 ~ 300bpm
- Resolution: 1bpm
- Precision: ��3bpm Pulse Rate
- Channel 2
- Measure & alarm range: 0 ~ 50 ���
- Resolution: 0.1 ���
- Precision (no sensor): ��0.1 ��� TEMP
- Etco2 (Optional)
- IBP modular (Optional)
- Touch screen (Optional)
- Trolley bracket (Optional)
- Hanging bracket (Optional)
- Monitor recorder (Optional)
- Wifi (Optional)
- C.O.modular
- BIS modular Optional
- 5 Leads: RA, LA, LL, RL, V
- Lead mode: ���,���, ���, aVR, aVL, aVF, V Increase: ��250�����500�����1000��� ��2000
- Sensitivity: > 200 uV (Peak-to-peak value)
- Input impedance: > 5 ( megohm )
- Bandwidth: Surgery 1 ~ 20 Hz
- Monitor 0.5 ~ 40 Hz
- Diagnostic 0.05 ~ 130 Hz
- CMRR 100dB
- Polarization Voltage: �� 300mV
- Baseline Recovering Time: After defibrillation< 3 seconds
- Signal Range: 8 mV ���Peak-to-peak value���
- Calibrating Signal: 1mV, precision ��5%
- Heart rate range���15-380bmp
- Heart rate accuracy:+/-1% ECG
- Method: RA-LL impedance
- Resp Impedance range: 0.3 ~ 3
- Base Impedance range: 200 ~ 4000
- Bandwidth: 0.1 ~ 2.5Hz
- Resp rate: Adult 0 ~ 120BrPM
- Neonatal/Pediatric 0 ~ 150BrPM
- Resolution: 1BrPM
- Precision: ��2 BrPM
- Asphyxia Alarm: 10���40 seconds RESP
- Method: Pulse wave oscillometry
- Work mode: Manual/ Auto/ STAT
- Measure interval of auto mode: 1,2,3,4,5,10,15,30,60,90,120,180, 240,480 minute(s)
- Measuring Time of STAT Mode: 5 minutes
- PR range: 30 ~ 250bpm
- Measure & alarm range: Adult SYS 40 ~ 270mmHg DIA 10 ~ 215mmHg MEAN 20 ~ 235mmHg Pediatric SYS 40 ~ 200mmHg DIA 10 ~ 150mmHg MEAN 20 ~ 165mmHg Neonatal SYS 40 ~ 135mmHg DIA 10 ~ 100mmHg MEAN 20 ~ 110mmHg
- Static pressure range: 0 ~ 300mmHg Precision: �� 3mmHg
- Pressure precision: Max. average error: ��5mmHg Max. standard deviation: ��8mmHg
- Overvoltage protection: Adult 300mmHg Pediatric 240mmHg Neonatal 150mmHg NIBP
- Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
- Measuring and alarm range
- ART 0 ~ 300 mmHg
- PA -6 ~ 120 mmHg
- CVP/RAP/LAP/ICP -10 ~ 40 mmHg
- P1/P2 -10 ~ 300 mmHg
- Press Sensor
- Sensitivity 5 uV/V/mmHg
- Impedance 300-3000
- Resolution: 1 mmHg
- Accuracy: ��2% or ��1mmHg, which great
- Actualization interval: about 1 Sec. IBP
- Side/Main stream
- Warm-up time:when the ambient temperature is 25 ���, the carbon dioxide curve(capnogram) can be displayed within 20/15 seconds, and all the specifications can be fulfilled within 2 minutes.
- Measurement range:0-150mmHg, 0-19.7%,0-20kPa (at 760mmHg), atmospheric pressure provided by the host.
- Resolution 0.1mmHg ���0-69mmHg 0.25mmHg��� 70-150mmHg
- Precision 0-40mmHg��� ��2mmHg 41-70mmHg��� ��5%���reading��� 71-100mmHg��� ��8%���reading��� 101-150mmHg�����10%���reading���
- Respiratory rate range 0- 150 BPM
- Respiratory rate accuracy: ��1 BPM CO2
- NIBP cuff & tube
- ECG cable & electrodes
- SpO2 sensor
- TEMP probe
- Lithium-ion battery
- Power cable
- Operator���s manual